Description
General description
The anti-theft security system works as a loop: the plastic-insulated optical fiber is attached to the solar panels and strung together in a circle. The optical fiber is connected directly to a controller that detects the cutting of the fiber. If a theft attempt breaks the fiber, the current optical controller detects the interruption of the light signal and triggers an alarm. The controller works perfectly between 0 and -30 dB optical power. (the attenuation is 25dB at 250 meters).
From the SOLAR FIBER controllers, we can set the notifications separately for each loop using a single jumper, thereby distinguishing the signals. We can even enter individual messages with a connected GSM module.
Attenuation of the optical cable
Plastic optical fiber is a polymer material that allows light to pass through from the inside and is also suitable for transmitting a light signal. However, this signal propagates along the fiber, it gradually loses strength: this is called attenuation.
At every meter in the optical fiber, we have to account for attenuation (= optical power loss): the more optical fibers are placed, the greater the attenuation will be thus the optical power at the end of the fiber will be lower.
Accessories related to installing the optical fiber (e.g. overstretched cable ties, tensioning screws, etc.) increase its attenuation.
Connection schemes
The SOLAR FIBER system does not require unique settings. They can be installed in the following ways:
- Transmitter-receiver mode (transmitter+receiver): when the optical fiber is laid as a loop and returns to the same device. When the optical fiber breaks, the light stops, thus generating a signal.
- transmitter (TX) or receiver (RX) mode: if the optical fiber is connected directly to another device (without a loop)
- amplifier mode: when the optical fiber enters and exits the same device, which amplifies the signal for an additional 300 m (approx).
Alarm signal
All SOLAR FIBER control panels have a normally closed (NC) electrical contact alarm output. The controllers can be connected in series, keeping their alarm zones separate or grouped. Alarm output data: 0.5 A/24 VAC, 0.5A/24 VDC
Parameters
Device power supply | We can provide the system with an optional external 12VDC power supply, which is optional |
Current consumption | 3.7V/2.8mA @ 0.01W (standby) |
Operating range | -20 - +50˚C |
Input | 1 tamper input a dry contact can be connected to it (e.g.:opening sensor, loop) |
Number of alarm outputs | 2 pcs, SOLAR1 and SOLAR2 |
Number of OC outputs | 3 Load capacity max. with a voltage of 20V |
Type of connectors | MC4 |
Insulation protection | IP65 |
Weights | 0,48 kg |
Module size | 16,9 x 13,5 x 8,9 cm (length x width x depth) |
Optional * | |
* Connectable battery type | ProBattery 2000mAh (max 2pcs) |